Detailed technical data
Features
System part |
Sensor with actuator |
Sensor principle |
Magnetic |
Number of N/O contacts |
1 |
Number of N/C contacts |
1 |
Number of signaling contacts |
0 |
Safe switch on distance Sao |
6 mm |
Safe switch off distance Sar |
31 mm |
Active sensor surfaces |
1 |
Actuation directions |
5 |
Safety-related parameters
Functions Interfaces
B10d parameter |
2 x 107 switching cycles (with small load) |
Type |
Type 4 (EN ISO 14119) |
Actuator coding level |
Low coding level (EN ISO 14119) |
Safe state in the event of a fault |
The switch has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit. |
Safe series connection |
None, only individual wiring (with diagnostics) |
Connection type |
Cable |
Length of cable
Cable diameter Conductor cross section Bend radius (with fixed installation) Bend radius (with moving cable) Cable material Conductor material
3m
5.8 mm
0.25 mm2
> 12 x cable diameter > 15 x cable diameter PVC
Copper
Display elements |
LEDs |
Mas información?