Protection class III (IEC 61140)
Contamination rating 3 (EN 60947-1)
Classification according to cULus Class 2
Usage category DC-13 (IEC 60947-5-1)
Rated insulation voltage Ui 32 V
Rated impulse withstand voltage Uimp 1,500 V
Supply voltage UV when an individual safety switch is connected
Sensor 24 V DC (19.2 V DC … 28.8 V DC)
Magnet 24 V DC (19.2 V DC … 28.8 V DC)
Supply voltage UV when a cascade is connected
Sensor 24 V DC (22.8 V DC … 28.8 V DC)
Magnet 24 V DC (21.6 V DC … 28.8 V DC)
Power consumption
Locking active 350 mA
Locking deactivated 50 mA
Switching frequency ≤ 0.5 Hz
Type of output Self-monitoring semiconductor outputs (OSSDs)
Output current (OSSDs) ≤ 100 mA
Diagnostic output ≤ 25 mA, short-circuit protected
Cable capacitance 400 nF (for OUT A and OUT B)
Response time 50 ms 1)
Release time 100 ms 1)
Risk time 100 ms 1)
Switch-on time 2.5 s
Locking principle Power to lock