Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 2 |
Factory setting |
oils; oil-based media |
Process connection |
threaded connection G 1/2 sealing cone |
Application |
Special feature |
Gold-plated contacts |
Media |
Liquids; viscous media; powder |
Cannot be used for |
See the operating instructions, chapter «Function and features». |
Probe length [mm] |
11 |
Tank pressure 0%
|
-1…40 |
MAWP (for applications according to CRN) 0%
|
40 |
Oil |
Medium temperature [°C] |
-40…100 |
Medium temperature short time [°C] |
-40…150; (1 h) |
Water |
Medium temperature [°C] |
-40…100 |
Medium temperature short time [°C] |
-40…150; (1 h) |
Electrical data |
Operating voltage [V] |
18…30 DC |
Current consumption [mA] |
< 50 |
Protection class |
III |
Reverse polarity protection |
yes |
Measuring principle |
capacitive |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2 |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; IO-Link |
Electrical design |
PNP/NPN |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
100 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring/setting range |
Factory setting |
oils; oil-based media |
Response times |
Response time [s] |
< 0.5 |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
Profiles |
Smart Sensor: Process Data Variable; Device Identification |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
1 |
Process data binary |
2 |
Min. process cycle time [ms] |
2.3 |
Supported DeviceIDs |
Type of operation |
DeviceID |
Default |
305 |
|
Operating conditions |
Ambient temperature [°C] |
-40…85 |
Note on ambient temperature |
Medium temperature: < 100 °C |
-40…60 °C |
Medium temperature: < 150 °C |
|
Storage temperature [°C] |
-40…85 |
Protection |
IP 68; IP 69K |
Tests / approvals |
EMC |
DIN EN 61000-6-2 |
|
DIN EN 61000-6-4 |
: open tanks |
DIN EN 61000-6-3 |
: closed tanks |
|
Shock resistance |
DIN EN 60068-2-27 |
50 g (11 ms) |
|
Vibration resistance |
DIN EN 60068-2-6 |
20 g (10…2000 Hz) |
|
MTTF [years] |
223 |
UL approval |
|
Mechanical data |
Weight [g] |
210 |
Materials |
stainless steel (1.4404 / 316L); PEEK; PEI; FKM |
Materials (wetted parts) |
PEEK; surface characteristics: Ra < 0,8 / Rz 4 |
Process connection |
threaded connection G 1/2 sealing cone |
Displays / operating elements |
Display |
switching status |
LED, yellow |
operating status |
LED, green |
|
Remarks |
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12; coding: A; Contacts: gold-plated |