Model | GL-R44H | |||
Detection capability | ø25 mm | |||
Total length | 880mm | |||
No. of beam | 44 | |||
Detection height | 860mm | |||
Protection height | 905mm | |||
Beam axis spacing/Lens diameter | 20 mm / ø5 | |||
Detecting distance | 0.2 to 15 m*1 | |||
Effective aperture angle | Max. ±2.5° (When operating distance is 3 m or more) | |||
Light source | Infrared LED (870 nm) | |||
Response time (OSSD) (ms) | Wire synchronisation, One-line or Optical synchronisation system (Channel 0) |
ON→OFF | 9.2 | |
OFF→ON | 52.6*2 | |||
All blocked→ON | 73.5*3 | |||
Optical synchronisation system (Channel A or B) |
ON→OFF | 12.9 | ||
OFF→ON | 58.2*2 | |||
All blocked→ON | 88.6*3 | |||
Detection mode | Turns on when no interruptions are present in the detection zone | |||
Synchronisation between the transmitter and receiver | Optical synchronisation or Wire synchronisation (Determined by wiring) | |||
Light interference prevention function | Prevents mutual interference in up to two GL-R systems. Optical synchronization: prevented by Channel A and B with setting switch Wire synchronization: prevented automatically |
|||
Control output (OSSD output) |
Output | 2 transistor outputs. (PNP or NPN is determined by the cable type) | ||
Max. load current | 500 mA*4 | |||
Residual voltage (during ON) | Max. 2.5 V (with a cable length of 5 m) | |||
OFF state voltage | Max. 2.0 V (with a cable length of 5 m) | |||
Leakage current | Max. 200 µA | |||
Max. capacitive load | 2.2 µF | |||
Load wiring resistance | Max. 2.5 Ω | |||
Supplemental output (Non-safety-related output) |
AUX | transistor outputs. (PNP or NPN is determined by the cable type) Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 5 m) |
||
Error output | ||||
Muting lamp output | Incandescent lamp (24 VDC, 1 to 5.5 W) LED lamp (load current: 10 to 230 mA) can be connected. |
|||
External input | When using a PNP output cable | EDM input Wait input Reset input Muting input 1, 2 Override input |
ON voltage: 10 to 30 V OFF voltage: Open or 0 to 3 V Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only) |
|
When using an NPN output cable | ON voltage: 0 to 3 V OFF voltage: Open or 10 V or more Up to the power voltage Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only) |
|||
Power supply | Power voltage | 24 VDC ±20%, ripple (P-P) 10% or less, Class 2 | ||
Current consumption (Max.) (mA) |
Transmitter | 66 | ||
Receiver | 77 | |||
Protection circuit | Reverse current protection, short-circuit protection for each output, surge protection for each output | |||
Approved standards | EMC | EMS | IEC61496-1, EN61496-1, UL61496-1 | |
EMI | EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA | |||
Safety | IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD) IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3) EN ISO13849-1:2015 (Category 4, PLe) UL508 UL1998 |
|||
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) | ||
Overvoltage category | II | |||
Ambient light | Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less | |||
Operating ambient temperature | -10 to +55 °C (No freezing) | |||
Storage temperature | -25 to +60 °C (No freezing) | |||
Operating relative humidity | 15 to 85 % RH (No condensation) | |||
Storage relative humidity | 15 to 95 % RH | |||
Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions | |||
Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | |||
Material | Main unit case | Aluminium | ||
Upper case/lower case | Nylon (GF 30%) | |||
Front cover | Polycarbonate, SUS304 | |||
Weight | Transmitter | 1220 g |
Mas información?, distribuidor, Argentina, Keyence Corporation.
Weight | 1,240 kg |
---|---|
Dimensions | 88 × 5,5 × 5,5 cm |