FS-MIP, KEYENCE, Manual Calibration Fibraoptica Sensor Fiber Amplificador PNP
Fibre Amplifier, Cable Type, Main Unit, PNP, FS-V/T/M series
Description
- Description: Sensor Amplifcador FS-M1P
- Weight: Approx 75 g
- Footnotes: *1 Only the FS-T1 and FS-M1 can provide stability outputs. *2 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less. 3 to 10 Units: -10 to 50C 14 to 122F, 11 to 16 Units: -10 to 45C 14 to 113F *3 When several units are connected, the ambient temperature requirement varies depending on the total number of units connected. When 3 to 10 units: -10 to +50C 14 to 122F When 11 to 16 units: -10 to +45C 14 to 113F When connecting several units, be sure to mount the units to a metallic DIN rail. Make sure that the output current does not exceed 20 mA.
- Type: Main unit
- Response time: 250 ?s (FINE)/500 ?s (TURBO)
- Output: PNP
- Light source: Red LED
- Sensitivity adjustment/Mode selection: 8-turn trimmer (with indicator), FINE/TURBO (switch-selectable)
- Operation mode: LIGHT-ON/DARK-ON (switch-selectable)
- Indicator lamp: Output: Red LED Stable operation: Green LED
- Timer function: ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)
- Control output: PNP open-collector 100 mA max. (40 VDC max.), Residual voltage: 1 V max.
- Stability output: PNP open-collector 50 mA max. (40 VDC max.), Residual voltage: 1 V max.*1
- Protection circuit: Reversed polarity protection, over-current protection, surge absorber
- Unit expansion: Up to 16 expansion units can be connected (a total of 17 units).*2
- Mutual interference suppression: FINE : 4, TURBO/SUPER: 8
- Rating – Power voltage: 12 to 24 VDC 10%, ripple (P-P): 10% or less
- Rating – Current consumption.: 35 mA or less
- Environmental resistance – Operating ambient luminance: Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.
- Environmental resistance – Operating temperature range: -10 to +55C 14 to 131F, No freezing*3
- Environmental resistance – Operating ambient humidity: 35 to 85% RH (No condensation)
- Environmental resistance – Vibration: 10 to 55 Hz, double amplitude: 1.5 mm 0.06″, 2 hours each in the X, Y and Z axis
- Environmental resistance – Shock resistance: 500 m/s2 in X, Y, and Z directions, 3 times respectively
- Case material: Polycarbonate