DT20-P244B, SICK, Sensor de medicion de dezplazamiento, 100…300mm, 24vdc, 400hz, 0,01 lin.
Precisión de repetición. ≥ 0,25 mm 1) 2) 3). Linealidad. ± 1 mm 3) 4). Tiempo de respuesta. ≥ 2,5 ms 2). Frecuencia de medición
Description
-
Mechanics/electronics
Supply voltage Vs |
DC 10 V … 30 V 1) |
Ripple |
≤ 5 Vpp 2) |
Power consumption |
≤ 1.8 W 3) |
Warm-up time |
≤ 10 min |
Housing material |
Metal (zinc diecast) |
Window material |
Plastic (PMMA) |
Connection type |
Male connector, M12, 5-pin, swivel connector unit |
Indication |
LC display, 2 x LED |
Weight |
135 g |
Dimensions (W x H x D) |
24.3 mm x 72.4 mm x 54.1 mm |
Enclosure rating |
IP65 (EN 60529) |
Protection class |
II |
-
Performance
Measuring range |
100 mm … 300 mm 1) |
Target |
Natural objects |
Repeatability |
≥ 0.25 mm 1) 2) 3) |
Linearity |
± 1 mm 3) 4) |
Response time |
≥ 2.5 ms 2) |
Measuring frequency |
≤ 400 Hz 1) |
Output time |
≥ 2.5 ms |
Light source |
Laser, red
visible red light |
Laser class |
2 (IEC 60825-1:2014, EN 60825-1:2014) |
Typ. light spot size (distance) |
3 mm x 6 mm (300 mm) |
Additional function |
Set moving average fast/medium/slow, switching mode: distance to object (DtO), teach-in of digital output, invertable digital output, teach-in of analog output, Invertable analog output, Multifunctional input: laser off / external teach-in / deactivated, switch-off display, lock user interface |
-
Interfaces
Digital output |
|
Number |
1 1) |
Type |
PNP |
Maximum output current IA |
≤ 100 mA |
|
Analog output |
|
Number |
1 |
Type |
Current output |
Current |
4 mA … 20 mA, ≤ 300 Ω |
Resolution |
12 bit |
|
Multifunctional input (MF) |
1 x MF 2) |
Additional information
Weight |
0,135 kg |
Dimensions |
2,4 × 7,2 × 5,4 cm |