ACOPOSinverter P74, 3x 380 to 500 V, 2.2 kW, integrated EMC filter and brake chopper, shield plate included in delivery, POWERLINK interface
Certifications | |
CE | Yes |
UL | UL E225616 Power conversion equipment |
KC | Yes |
Specified on nameplate | 2.2 kW (3 HP) |
Mains input voltage | 3x 380 VAC -15% to 500 VAC +10% |
Frequency | 50 to 60 Hz ±5% |
Apparent power (at 500 VAC) | 5.7 kVA |
Max. assumed short-circuit current (Isc) (short-circuit current at connection point) |
5 kA |
Inrush current | Max. 10 A |
Mains current | |
At 380 VAC | 8.7 A |
At 500 VAC | 6.6 A |
Power dissipation at nominal load and nominal clock frequency | 78 W |
Integrated EMC filter | Yes |
With integrated filter | |
Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network) |
– |
Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network) |
C2 level of 4 to 12 kHz with 5 m cable |
Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system) |
5 m |
With add-on filter | 8I0FT015.200-1 |
With add-on filter | |
Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network) |
C1 level of 2 to 16 kHz with 20 m cable |
Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network) |
C2 level of 2 to 16 kHz with 50 m cable |
Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system) |
50 m |
Nominal output current | 5.5 A |
Derating of continuous output current depending on ambient temperature | |
At nominal clock frequency (4 kHz) | No derating (up to 50°C) |
Other clock frequencies | The derating curves are included in the installation instructions, which can be downloaded from www.br-automation.com. |
Derating of continuous output current depending on installation elevation | |
Starting at 1000 m above sea level | 1%, per 100 m |
Max. transient current for 60 s | 8.3 A |
Max. transient current for 2 s | 9 A |
Output frequency range | 0.1 to 599 Hz |
Nominal clock frequency | 4 kHz |
Clock frequency | |
Min. | 2 kHz |
Max. | 16 kHz |
Braking torque | |
With braking resistor | Up to 170% of the nominal motor torque |
Max. motor cable length | |
Shielded cable | 50 m |
Non-shielded cable | 100 m |
Motor control profiles | |
Induction motor | Sensorless vector control: 1. With V/f characteristic curve for constant torque → Default profile 2. With V/f characteristic curve for quadratically increasing torque → Energy-saving profile, e.g. for fans and pumps Sensorless slip control: 1. With V/f characteristic curve for constant torque → Default profile 2. With V/f characteristic curve for constant torque (6 f ranges) → Profile for individual special applications 3. With V/f characteristic curve for quadratically increasing torque → Energy-saving profile, e.g. for fans and pumps |
Synchronous motor | Sensorless vector control: 1. With V/f characteristic curve for constant torque → Default profile |
Main protective functions of inverter | Thermal protection against power stage overheating Protection against short circuits between motor phases, overcurrent between output phases and ground, overvoltages on the DC bus, exceeding the speed limit. Safety function for: Overvoltage and undervoltage of the mains supply, mains phase failure with 3-phase power supply |
Integrated dynamic brake transistors | Yes |
Min. resistance value (external) | 54 Ω |
Input voltage | 24 VDC (-15%/+20%) |
Current | Max. 1.1 A |
Output voltage 24 VDC | 24 VDC (-15%/+20%) |
Output voltage 24 VDC | |
Max. output current at 24 VDC | 100 mA |
Output voltage 10 VDC | 10 VDC (-0%/+10%) |
Output voltage 10 VDC | |
Max. output current at 10 VDC | 10 mA |
POWERLINK | |
Type | Type 2 |
Quantity | 6 |
Nominal voltage | 24 VDC (max. 30 V) |
Input circuit | Source or sink |
Input circuit | |
Current consumption | 7 mA |
Electrical isolation | |
Input – ACOPOSinverter | Yes |
Input – Input | No |
Sampling time | 8 ms ±0.7 ms |
Input impedance | 3.5 kΩ |
Digital input 5 | |
Max. input frequency | 20 kHz |
Quantity | 1 |
Nominal voltage | 24 VDC |
Input impedance | 1.5 kΩ |
Input impedance | |
Current consumption | 16 mA |
Switching threshold | |
Low | <2 V |
High | >17 V |
Electrical isolation | |
Input – ACOPOSinverter | Yes |
Input – Input | No |
Input circuit | Sink |
Sampling time | 4 ms |
Quantity | 3 |
Electrical isolation | |
Input – Input | No |
Input – ACOPOSinverter | Yes |
Input | |
Voltage | 0 to 10 V, ±10 V |
Current | 0 to 20 mA (or 4 to 20 mA) |
Resolution | 10-bit |
Sampling time | 2 ms |
Input impedance | |
Voltage | 30 kΩ |
Current | 250 Ω |
Quantity | 1 |
Nominal voltage | 24 VDC |
Max. voltage | 30 VDC |
Output circuit | Source or sink |
Sampling time | 2 ms |
Max. current | 100 mA |
Quantity | 2 |
Nominal voltage | 30 VDC / 250 VAC |
Switching capacity | R1, with resistive load (cos phi = 1): 3 A at 250 VAC, R1, with resistive load (cos phi = 1): 4 A at 30 VDC, R1, R2, with inductive load (cos = 0.4 and L/R = 7 ms): 2 A at 250 VAC, R1, R2, with inductive load (cos = 0.4 and L/R = 7 ms): 2 A at 30 VDC, R2 with resistive load (cos phi = 1): 5 A at 250 VAC, R2 with resistive load (cos phi = 1): 5 A at 30 VDC |
Variant | |
Relay 1 | 1 changeover contact |
Relay 2 | 1 normally open contact |
Electrical isolation | |
Output – ACOPOSinverter | Yes |
Output – Output | No |
Response time (max.) | 2 ms |
Quantity | 1 |
Output | 0 to 10 V or 0 to 20 mA |
Electrical isolation | |
Output – ACOPOSinverter | Yes |
Output – Output | No |
Max. load impedance | |
Voltage | 470 Ω |
Current | 800 Ω |
Update time | 2 ms |
Resolution | 10-bit |
Degree of protection per EN 60529 | IP20 |
Relative humidity per IEC 60068-2-3 | 5 to 95%. non-condensing No dripping water |
Maximum installation elevation | Up to 2000 m |
Max. pollution degree per IEC/EN 61800-5-1 | 2 (non-conductive pollution) |
Ambient conditions per IEC 60721-3-3 | Class 3C3 and 3S3 |
Operating position | Vertical mounting orientation ±10% |
Temperature | |
Operation | -10 to 50°C without derating 50 to 60°C with derating |
Storage | -25 to 70°C |
Max. vibration resistance | 1 gn 13 to 200 Hz EN/IEC 60068-2-6 1.5 mm peak to peak 3 to 13 Hz EN/IEC 60068-2-6 |
For revision information, see the following model numbers:
8I74T400220.010-1
8I0IF108.400-1
Somos Wartung Automation, Lider en equipamientos, repuestos y service B&R para la automatizacion en Argentina hace 23 anos.
Hacemos service, backup , reparaciones de equipos B&R en Argentina.
Consulte su presupuesto.
Peso | 4 kg |
---|